$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
This protocol uses two setups (Figure 1) to acquire four different readouts collected from flies subjected to a bacterial infection. These outputs include 1) sleep/wake behavior; 2) survival outcome; 3) bacterial load in the fly; and 4) real-time measurement of NFκB reporter activity in vivo. In combination with the genetic tools that are available in Drosophila, these measurements provide mechanistic insight into the molecular link between immune function and behavior.
1. Measure Locomotor Activity and Sleep in Flies
- The setup used to measure locomotor activity and sleep in flies, which includes the Drosophila activity monitoring system (DAM2, Trikinetics), incubators, dark room, and the preparation of experimental animals and activity tubes, has been described previously6. The same approach is used here, with some minor modifications.
- The lighting of the incubator is controlled by the incubator itself. Therefore, it is important to synchronize the time setting among computer and incubators.
- Activity tubes are cleaned for re-use by boiling on a hot plate in de-ionized water. A small amount of detergent is added for the first boil, tubes are well-rinsed and boiled twice more. If yarn is used to plug the tube, used activity tubes (containing food, wax, fly and yarn) can be cleaned without prior removal of the yarn.
- Prior to initiating an experiment, place cultures containing late pupal staged flies in incubators for three to four days to adapt to experimental lighting and other environmental conditions. Light:dark or constant conditions have been commonly used to measure sleep behavior. In this example, flies are acclimated to constant light to eliminate the influence of the circadian clock on the immune response and behavior2,7,8 . As described in Figure 1A, load 1-4 day old flies into the Trikinetics DAM2 activity monitors as described6, and record for a minimum of three days prior to the infection.
2. Infect Flies with a Pathogenic Strain of Bacteria
- The protocol described here is specific for S. marcescens, which are easy to grow and maintain. Protocols for long-term storage and culture conditions for other bacterial species will vary. S. marcescens are stored in 15-50 % glycerol at -80 °C. To prepare for long-term storage, mix 2 volumes of overnight bacterial culture (O.D. 600 = 0.5 - 1.0) to 1 volume of autoclaved 50% glycerol in 1.5 ml microcentrifuge tubes. This will result in a final glycerol concentration of 17%. Store tubes at -80 °C. To prepare a short-term in-use source of bacteria, scrape the frozen stock with a sterile 200 μl pipette tip and perform a three-way streak on an LB agar plate. Incubate the plate overnight at 37 °C to get isolated colonies. Store the plate at 4 °C.
One day before the scheduled infection, pick a single colony from the LB agar plate with a sterile 200 μl pipette tip and submerge the tip into a culture tube containing 5 ml LB medium. Grow bacteria overnight, or up to 16 hr inside an incubator shaker at 37 °C and 250 rpm until it reaches the exponential growth phase. Measure the concentration with a spectrophotometer at OD600. The concentration in this phase ranges from 0.5 to 1. If the concentration is too high, subculture the bacteria and grow for another several hours to get an optimal concentration. Perform the procedure near a flame source. Some bacterial strains are engineered for antibiotic resistance and are grown and selected for appropriate antibiotic added to the medium. S. marcescens (ATCC #8100) are not antibiotic resistant and are therefore grown in sterile medium without antibiotic. To verify sterile technique, do a mock culture without bacteria as a control.
The solution to infect flies contains bacteria (diluted to OD600=0.1) and 1% food coloring (Brilliant Blue FCF) in PBS. Prepare a solution for injection control by adding equivalent amount of LB medium used in infection solution and 1% blue food coloring in PBS. Store solutions on ice.
- Prepare glass needles for injecting the flies. Pull glass capillaries (o.d. = 1 mm, i.d. = 0.58 mm, WPI) to a fine tip using a micropipette puller (Narishige). Under a dissecting microscope, use fine forceps to break off the tip of the needle so that the opening is large enough to fill with injection fluid by applying suction with a syringe, but small enough to minimize damage to the fly during the injection process. After breaking the tip, the tip size should be around 40-50 μm. The glass needle is attached to a 3 cc plastic syringe with a length of tubing. The flow of injection medium is controlled manually applying positive pressure or suction with the syringe. Avoid contaminating the rubber tubing with injection fluid, as the syringe apparatus is used for both infection and control injections.
- Anesthetize flies by putting them on a CO2 pad. CO2 is passed through a sealed container of water to humidify the pad and to reduce static electricity, which can complicate manipulation of flies on the pad. Inject flies by poking the glass needle into the region above the scutellum of the dorsal thorax. The passing of injection medium into the fly is verified by the food coloring - flies turn blue as the food coloring spreads through the system. The dose of bacteria that flies receive can be quantified as described in Section 3, below. Some experimental designs include a control group that receives aseptic injury by injecting flies with PBS and food coloring but without bacteria.
3. Determine the Bacterial Load
One approach to evaluating the immune response against bacterial infection is to determine the bacterial load post infection. D. melanogaster is a great model to determine this parameter because the whole fly can be homogenized to estimate the total bacterial numbers within an individual. The rationale behind this protocol is that when grown on a solid medium such as Luria broth (LB) agar on a Petri dish (LB plate), a single bacterium forms a visible distinguishable colony. Therefore, by homogenizing infected flies in LB liquid medium, generating serial dilutions of the homogenate, and spreading the diluted homogenate onto LB plates, the number of bacterial cells infecting a fly can be determined. A control group of flies injected with PBS and food coloring but without bacteria should be used to verify that the infection was not contaminated with other bacterial species. There should be no colonies on the LB agar plate in this condition.
- Autoclave all materials that will be used for this procedure before performing the actual homogenization step. This includes 200 μl pipette tips cut with scissors, LB media, and pestles used for the homogenization. Prepare plates by pouring autoclaved LB/agar medium into 10 cm sterile Petri dishes at least 1 day before homogenizing flies.
- Anesthetize and collect flies in 1.5 ml microcentrifuge tubes and store tubes on ice.
- Perform the homogenization near a flame to prevent contamination. A control homogenization containing flies without infection is recommended especially when using a bacterial strain such as S. marcescens, which are not antibiotic resistant. Homogenize a minimum of 2 groups of 10 flies each per experimental condition. The number of flies used per homogenate is determined by the experimenter. Some groups have used one fly per homogenate, which is useful for evaluating variation in bacterial load between individual flies8, while others have used from 3-10 flies per homogenate to compare across genotype or experimental condition9-12.
- Add 400 μl LB medium to each microcentrifuge tube containing flies and homogenize using a small motor and pestle (Kontes).
- Using sterilized cut pipette tips, serial dilute the homogenate 1:10 by adding 20 μl homogenized LB/bacterial medium to 1.5 μl microcentrifuge tube containing 180 μl LB medium. Cutting pipette tips prevents blockage from fly debris and ensures that an appropriate volume is being transferred.
- Dilution factor is determined empirically and depends on the genotype of the fly, the bacterial strain used, and experimental condition. For wild type flies infected with S. marcescens, use dilutions of 1:102 or 1:103 for flies homogenized immediately post-infection, and dilutions of 1:104 or 1:105 for flies homogenized 24 hr post-infection.
- Add 100 μl LB/bacterial medium from the microcentrifuge tubes containing the final dilution and spread the medium on an LB plate using glass balls (VWR) to ensure an even distribution.
- Discard the glass balls into 100% EtOH solution. Place the LB plates in a 37 °C incubator overnight.
- As an optional step, use an imaging system with visual light to obtain an image of the LB plates (FluorChem 8900; Alpha Innotech). Count the numbers of colonies either on the plate itself or from the image of the plate using the counting tool on Photoshop software (Adobe Photoshop CS3).
- Calculate the number of colony-forming units per fly using the formula: [n /(N *D *v)]*V; where n= number of colonies grown on the LB plate; N=the number of the flies pooled in one microcentrifuge tube; D= dilution factor; and v = volume of solution spread onto each plate; V = initial volume of the homogenate.
4. Evaluate Sleep and Survival Duration After Infection
- For flies that are not harvested for measuring bacterial load, continue monitoring behavior for another 7-10 days. Survival duration is influenced by genotype of the fly, environmental conditions, and bacterial species used for infection.
- After ~10 days, terminate the experiment, download and process behavioral data as previously described6. Insomniac2 custom software, which is based in Matlab, is used to analyze sleep parameters. It is important to eliminate dead flies from the behavioral analysis. Normally, this restricts analyses to within the first day after infection, depending on the type of infection and fly genotype. Death in the assay is indicated by the time all activity counts have reached zero. To facilitate analysis of survival, Drosonex, custom software written in Microsoft Visual C++ 6.0, is used to process raw data files from the Trikinetics DAM system. The software reports as Excel files, survival duration of each fly (in hours), compiles activity data from all monitors into a single spreadsheet, and reports the percent flies surviving over time as set by the user. The Excel files are designed to integrate into other statistical software packages for further analysis.
5. Measure NFκB Activity During Infection Using a Luciferase Reporter Assay
Transgenic κB-luc flies used in this assay were generated previously as described in Kuo et al., 20102. Briefly, the κB-luc reporter contains 8 repeats of an NFκB binding sequence that were inserted into a promoter upstream of a luciferase open reading frame.
- Adjust flies to experimental lighting conditions as described in section 1.2. In this example, 1-4 day old κB-luc flies are housed in vials containing a 5% sucrose, 2% agar food medium and placed in constant light (LL) for 2 days to reach the same age as other flies during infection.
- Prepare a 96-well microplate for flies. Each well contains 2 layers of food medium (Figure 2); the top layer contains luciferin, the substrate of luciferase. Add 300 μl of a 5% sucrose, 2% agar solution to each well and allow to solidify. Next, add a 50 μl top layer to each well containing 5% sucrose, 1% agar, and 2 mM luciferin (Gold BioTechnology, Inc.). Luciferin concentrations used for measuring reporter activity in Drosophila have varied in the literature, and have been as low as 100 μM13. The concentration required can be determined empirically. Between dispensing the food layers, cover the plate with a fine mesh cloth to facilitate drying while maintaining sterility. The plate should be allowed to dry thoroughly, up to one hour, in order to prevent flies from getting stuck in condensation droplets. Because luciferin is light-sensitive, avoid exposing plates to light more than necessary.
- Apply a clear adhesive film (Top-Seal-A; Perkin Elmer) to a 96-well microwell plate and perforate using a fine needle at a quantity of 2 holes per well. These holes will not only allow air exchange to each well, but will also provide a way to anesthetize flies on an individual basis. Using a sharp blade and straight edge, introduce a cut between each column. This will provide an easy way to load/unload flies in groups of 8 at a time.
To load flies into the microwell plate, remove the vials from the incubator and anesthetize flies on a CO2 pad. Load flies one-by-one to each well column-by-column. Should a fly inadvertently get stuck to the adhesive seal, leave the fly alone as they are often able to free themselves without intervention. Return the microwell plate to the incubator in LL for 8-24 hr to adjust to the new environment and to consume the luciferin substrate.
- Culture bacteria, S. marcescens, and prepare a solution for infection as described above.
- Anaesthetize the flies by using a micropipette tip attached to a low-pressure CO2 line. Place the micropipette tip directly above the ventilation holes made for each well. Take caution to ensure that the CO2 pressure is high enough to anaesthetize the fly, but low enough to avoid injury to the fly. In groups of eight, individually transfer each fly to a CO2 pad, and infect as described above. After infection, return each fly to its original well and reseal the microplate.
- Measure luminescence (TopCount-NXT Luminescence and Scintillation Counter; Perkin-Elmer). The TopCount luminescence counter contains a stacking cassette for plates, which allows for programmed and automated readings continuously at desired increments for any length of time (usually up to five days). This feature is not available on all instruments, and data collection for experiments performed with other instruments may therefore be less frequent. The luminescence counter is housed in a room with a controlled temperature and lighting schedule. When loading plates into the stacking cassette, stack the plates containing the flies between clear blank plates to ensure that flies receive light. Program the luminometer according to manufacturer's specifications to collect readings every hour for a minimum of 24 hr. In this example, the detectors are programmed to read each well for 10 sec and to express the result as counts (arbitrary units) per second. This value is averaged across 3 readings per well. Export the data files to a spreadsheet and perform a standard analysis, graphing the results of luminescence.