A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Rat Heterotopic Abdominal Heart/Single-lung Transplantation in a Volume-loaded Configuration

8K views

⸱

DOI:

10.3791/52418

⸱

May 29th, 2015

 ,  , 

In This Article

Summary

We describe a novel technique for heterotopic abdominal heart-lung transplantation (HAHLT) in rats. The transplant configuration results in a partially loaded graft circulation, allowing direct functional assessment. This model may be employed for acute or chronic studies of function and immunologic status of the transplanted graft.

Abstract

Herein, we describe a novel technique for heterotopic abdominal heart-lung transplantation (HAHLT) in rats. The configuration of the transplant graft involves anastomosis of donor inferior vena cava (IVC) to recipient IVC, and donor ascending aorta (Ao) to recipient abdominal Ao. The right upper and middle lung lobes are preserved and function as conduits for blood flow from right heart to left heart.

There are several advantages to using this technique, and it lends itself to a broad range of applications. Because the graft is transplanted in a configuration that allows for dyamic volume-loading, cardiac function may be directly assessed in vivo. The use of pressure-volume conductance catheters permits characterization of load-dependent and load-independent hemodynamic parameters. The graft may be converted to a loaded configuration by applying a clamp to the recipient’s infra-hepatic IVC. We describe modified surgical techniques for both donor and recipient operations, and an ideal myocardial protection strategy. Depending on the experimental aim, this model may be adapted for use in both acute and chronic studies of graft function, immunologic status, and variable ventricular loading conditions. The conducting airways to the transplanted lung are preserved, and allow for acute lung re-ventilation. This facilitates analysis of the effects of the mixed venous and arterial blood providing coronary perfusion to the graft.

A limitation of this model is its technical complexity. There is a significant learning curve for new operators, who should ideally be mentored in the technique. A surgical training background is advantageous for those wishing to apply this model. Despite its complexity, we aim to present the model in a clear and easily applicable format. Because of the physiologic similarity of this model to orthotopic transplantation, and its broad range of study applications, the effort invested in learning the technique is likely to be worthwhile.

Introduction

The first rodent model of heterotopic abdominal heart transplantation (HAHT) was described by Abbott and colleagues in 19641. This technique, and subsequent modifications have been widely applied to characterize transplant graft function and immunologic status. The majority of HAHT techniques described involve a non-volume loaded heart2,3. Models of HAHT involving volume-loaded ventricles have been described, but they are frequently limited in one or more respects.

Heterotopic abdominal heart-lung transplantation (HAHLT) with a volume-loaded left ventricle (LV) has been described previously. Chen and colleagues4

Access restricted. Please log in or start a trial to view this content.

Protocol

All animals were housed and cared for in accordance with National and Institutional guidelines for the care and use of laboratory animals. Ethics approval for this protocol was granted by the University of British Columbia’s Animal Care Committee. Male, Sprague-Dawley rats weighing between 300 - 450 g were used for this protocol.

1. Donor Operation

  1. Have approximately 100 ml of cardioplegia (RT) in a cylindrical flask connected to long intravenous (IV) catheter tubing by a 3-way stopcock. Use a stand to elevate the flask to approximately 80cm above the operative surface, enabling cardioplegia delivery by gravity.
  2. ....

Access restricted. Please log in or start a trial to view this content.

Results

The HAHLT technique described above is highly technical and requires close attention to detail. Table 1 highlights some of the key factors associated with successful versus unsuccessful procedures, and can be used as a guide for troubleshooting technical difficulties.

After the recipient aorta is unclamped, the graft coronary arteries should be seen to fill with oxygenated blood. Accordingly, the myocardium should become pink and well perfused. In technically successful experi.......

Access restricted. Please log in or start a trial to view this content.

Discussion

Success with the technique described here will be predicated on several factors. Key among them will be ensuring stability of both donor and recipient animals, adopting meticulous operative technique that is safe and associated with minimal blood loss, ensuring complete cardioplegic arrest with uniform graft cooling, minimizing total ischemic time, and adequately de-airing the graft. As acknowledged above, the technique’s technical complexity is its chief limitation.

We have advanced pre.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

Mark J. Kearns receives support from the UBC Clinician Investigator Program (awarded through the Royal College of Physicians and Surgeons of Canada), and the UBC 4YF Doctoral Fellowship.

John H. Boyd is a National Sanitorium Association and Michael Smith Foundation for Health Research Scholar. Funding through CIHR. The authors wish to thank Dr. M. Allard and Richard Wamboldt for their assistance with setup and maintenance of perfusion equipment.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Celsior Cardioplegic SoutionGenzymeThe solution is kept on ice throughout the procedure. We prepare our own solution, with slight modifications.
Rodent VentilatorHarvard ApparatusModel 683
Vital Sign MonitorNoninModel 9847VDisplays SpO2 and heart rate.
IV CannulaeJelco306324 - 26 G x 3/4" cannulae.
IV TubingCareFusionMP9259-CShort-length connector tubing (18 cm).
Surgical ClipsTeleflex Medical001204Horizon titanium ligating clips.
SuturesEthicon, SharpointLA54G, AK-01073-0 silk reel, and 9-0 prolene suture (single-armed, DR5 needle).
Surgical InstrumentsNot ApplicableNot ApplicableThe instruments used are generic, and can be purchased from any surgical supply company.

References

  1. Abbott, C. P., Lindsey, E. S. A technique for heart transplantation in the rat. Arch Surg. 89 (1964), 649-652 (1964).
  2. Ma, Y., Wang, G. Comparison of 2 heterotopic heart transplant techniques in rats: cervical and abdominal heart. Exp Clin Transplant.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Heterotopic Abdominal Heart Lung TransplantationRat Heart Lung GraftVolume Loading ConfigurationInferior Vena Cava AnastomosisAscending Aorta AnastomosisPressure Volume Conductance CatheterMyocardial Protection StrategyAcute Lung Re-ventilationDynamic Volume Loading AssessmentSurgical Training Requirement