-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Environment
Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evalua...
Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evalua...
JoVE Journal
Environment
This content is Free Access.
JoVE Journal Environment
Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity

Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity

Full Text
9,350 Views
11:19 min
March 7, 2016

DOI: 10.3791/53555-v

Linda M. Brennan1, Mark W. Widder1, Michael K. McAleer2, Michael W. Mayo2, Alex P. Greis2, William H. van der Schalie1

1U.S. Army Center for Environmental Health Research, 2Nanohmics, Inc.

Summary

This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial cells for use in a field portable electric cell-substrate impedance sensor. The protocol for running a rapid drinking water toxicity test with the sensor is also described.

Transcript

The overall goal of this procedure is to demonstrate how to use a biosensor to evaluate the toxicity of drinking water samples. This is accomplished by creating biochips which contain a monolayer of rainbow trout gill cells and then using them as part of an impedence-based biosensor. This procedure provides a way to rapidly detect chemical toxicity in drinking water supplies at levels that are relevant to human health.

The main advantages of this technique are that the biochips can be used under field conditions, they can be stored cold for up to nine months without any care or maintenance of the cells, and that they are at a ready state for testing and can be used at any point after removal from refrigeration. Demonstrating this procedure will be Jordan McNairn, an undergraduate student from our laboratory. The day before cell seeding, remove the biochips from their packaging and place them into sterilized plastic instrument cases.

Attach one of the tubing assemblies to the syringe and draw up a 20%bleach solution into a 20 milliliter syringe. Inject two milliliters of the solution into each channel of the biochip. When finished, allow the biochips to sit for one hour with the bleach solution.

After one hour, use a sterile one-milliliter syringe fitted with a male slip luer assembly attached to a vacuum line to aspirate the bleach solution from both channels. After aspirating the bleach from the biochip, attach a sterile tubing assembly with male slip luers at each end to the biochip to use as a drain while rinsing the biochips. Then, draw up sterile water into a 20 milliliter syringe, and flush each channel of the chip with five milliliters of water.

Vacuum aspirate the water as before. And place the biochips back into the plastic instrument cases. Leave the biochips in the bio-safety hood until the next day.

One hour prior to seeding the biochips, inject two milliliters of a 10 micrograms per milliliter fibronectin solution into each channel of the biochip. Incubate the biochips in the bio-safety hood for 60 minutes, and then vacuum aspirate the fibronectin solution. Finally, place two sterile biochip tubing assemblies onto the ports of the biochips, and set the biochips aside until the cells are ready for seeding.

Remove one confluent T-175 flask containing rainbow trout gill epithelial cells from the incubator, and place it into the bio-safety hood. One confluent T-175 flask will be able to seed approximately 16 biochips. Aspirate off the media from the cells.

Rinse them with PBS, and aspirate off PBS. And then add six milliliters of Trypsin-EDTA solution to the cell layer. Incubate the flask at room temperature for about five minutes.

Then, add 15 milliliters of complete L-15 cell culture media to each flask, to deactivate the trypsin. Take a small aliquot from the cell suspension and use a hemocytometer to measure the concentration of the cells. View the cells using a bright field microscope equipped with a 10x objective.

Then, calculate the current cell concentration and adjust the cell suspension to a concentration of a quarter of a million cells per milliliter. Next, use a sterile 20 milliliter syringe to inject 2.5 milliliters of the cell suspension into the outer port of each channel of the biochip. Allow the extra cell suspension to flow out of the tubing into a waste container.

Then create an enclosed loop for each biochip channel by inserting the free end of the hose with a luer fitting into the outer port for each channel. Next, moisten a paper towel with 70%ethanol and use it to wipe any excess media off of the closed loops. Then, place the biochips back in a plastic box.

On days four and seven, remove the biochips from the incubator. And change the media in the biochips with temperature-equilibrated complete L-15 cell culture media. After the day seven feeding, remove and discard the hoses from the chips and insert the autoclave drain plugs into the biochips.

Place the biochips in a box in a six degree Celsius incubator until they are used for testing. Remove the ECIS test reader and supplies from the carrying case, and then turn on the reader. Also, take out one of the prepared biochips from the six degree Celsius incubator and place it onto a paper towel.

Using a 10 milliliter syringe, dispense 10 milliliters of control water into a labeled 0.5-ounce clear plastic control jar. Be sure to remove bubbles for an accurate measurement. Then, use a separate syringe and dispense 10 milliliters of the test sample into a 0.5 ounce clear plastic test jar.

Next, remove two powdered media vials. Open one of the powdered media vials and pour the entire contents of one vial into the jar with the control water, dropping the entire vial into solution as well. Repeat this procedure with the test jar.

Then, cap and shake the jars to ensure that the powder is completely dissolved. Fill the blue 10 milliliter syringe with nine milliliters of the control solution. And the red 10 milliliter syringe with nine milliliters of the test solution from their respective vials.

Remove any existing air bubbles from the syringes. Next, remove the plugs from the biochip ports and attach the drain. Place the biochip into the removable plastic tray in the ECIS reader, close the lid, and then attach the filled syringes to the outer biochip ports.

Finally, attach the syringe plungers. From the main screen of the reader, select Next to initiate the pre-test. The software will then check the initial impedances.

If the impedances are within range, the screen will register Cartridge passed"and instruct the user to select Next. Then, enter sample information using a soft keyboard, and then select Accept when finished. At this point, two minutes of impedance data will be collected from the inserted biochip, and an onscreen timer will count down time.

After two minutes, hit Next. When prompted by a flashing green box to Inject samples now"inject the control and test media from the attached syringes simultaneously into the biochip channels. Leave the syringes in place on the biochips when finished.

If the ECIS reader software determines that the treatment channel is statistically different from the control channel at any point during the test, the onscreen display will indicate that the sample is contaminated. Otherwise it will indicate that no contamination is detected at the end of the monitoring period. Record test results as Contaminated"or Not contaminated"for each sample.

At the end of the test run, remove and discard the biochip. Rinse and air-dry the syringes, the test vials and the removable plastic tray which housed the biochip during the tests. 13 chemicals, shown here, were selected for testing as representatives of a broad spectrum of toxic industrial compounds that could be possible contaminants of drinking water.

During the testing, nine of the 13 were detected by electric cell substrate impedance sensing within an hour, at concentrations that are relevant to human health. Typical outputs that would be seen following an electric cell substrate impedance sensing test are shown here. Contaminated samples end up with significantly lower impedance levels, when compared to the control, clean water samples.

After watching this video, you should have a good understanding of how to prepare a biochip with a monolayer of rainbow trout gill epithelial cells and to subsequently use that biochip in an impedance-based toxicity test for the evaluation of drinking water toxicity. While attempting this procedure, it's important to remember to work aseptically in preparing the biochips, and also to keep the biochips refrigerated until they are used. Each biochip can only be used once and then must be discarded.

Once mastered, the biochip preparation can be done in about 10 minutes. This is an estimate, because chips are prepared in batches. Sample impedance testing, including sample preparation takes about one hour and 10 minutes if it's performed properly.

Following this procedure, other methods such as analytical chemistry can be performed on a sample that produced a contaminated result, in order to identify the suspected chemical or chemicals. Development of this technique paves the way for researchers interested in water toxicity sensing to utilize technology using rainbow trout gill epithelial cells and impedance sensing. We hope that you will find the techniques useful and look forward to future innovations that these new capabilities may help to facilitate.

Thank you and have a great day.

Explore More Videos

Artificial IntelligenceAI Writing AssistantAI CopywritingText GenerationContent CreationWriting AutomationAI-powered Content Production

Related Videos

A Microfluidic Chip-Based Method for Rapid Neutrophil Chemotaxis Analysis Using Whole Blood

03:54

A Microfluidic Chip-Based Method for Rapid Neutrophil Chemotaxis Analysis Using Whole Blood

Related Videos

472 Views

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells

15:41

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells

Related Videos

15.3K Views

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis

14:53

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis

Related Videos

17.7K Views

Designing Microfluidic Devices for Studying Cellular Responses Under Single or Coexisting Chemical/Electrical/Shear Stress Stimuli

10:35

Designing Microfluidic Devices for Studying Cellular Responses Under Single or Coexisting Chemical/Electrical/Shear Stress Stimuli

Related Videos

9.3K Views

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

13:42

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

Related Videos

12.3K Views

Regeneration of Arrayed Gold Microelectrodes Equipped for a Real-Time Cell Analyzer

12:47

Regeneration of Arrayed Gold Microelectrodes Equipped for a Real-Time Cell Analyzer

Related Videos

7.5K Views

Fabrication and Validation of an Organ-on-chip System with Integrated Electrodes to Directly Quantify Transendothelial Electrical Resistance

10:51

Fabrication and Validation of an Organ-on-chip System with Integrated Electrodes to Directly Quantify Transendothelial Electrical Resistance

Related Videos

16.8K Views

A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency

07:43

A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency

Related Videos

23K Views

Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay

08:22

Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay

Related Videos

10K Views

Electric Cell-Substrate Sensing for Real-Time Evaluation of Metal-Organic Framework Toxicological Profiles

04:53

Electric Cell-Substrate Sensing for Real-Time Evaluation of Metal-Organic Framework Toxicological Profiles

Related Videos

1.5K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2025 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code