The indispensable role of central venous catheters (CVCs) in patient care is owed to their convenience, favorable safety profile, and versatility1. Functions of a CVC include reliable access for total parenteral nutrition, hematopoietic stem cell transplantation, plasmapheresis/apheresis, and efficient fluid, blood, or co-drug administration2. In veterinary medicine, CVCs also minimize animal discomfort via the rapid dilution of irritant drugs and blood sampling without repeated venipuncture3. Despite their broad applications, the use of CVCs in large animal research still presents several considerable challenges4.
Percutaneous CVC placement via a guidewire or introducer catheter can be difficult for non-veterinary researchers, particularly in animals with deep venous structures5. An improper CVC installation technique may result in inadvertent placement into nearby structures, necessitating ultrasound-guided placement or a postprocedure radiography of the positioning6. However, compared to human operating rooms, ultrasounds are not readily available in many large animal research laboratories. Further, long-term use of indwelling catheters can result in line kinking, puncture, infection, or extrication by animals, with the possible disruption of timely treatment, clinical monitoring, and research outcomes4,7. Replacement of the CVC requires additional resources, including material procurement, surgical scheduling, fasting time, and radiographic access. CVC-related complications can therefore create significant technical and financial barriers or a disruption to productive translational research, particularly in swine. Contamination by food or feces, scratching against cage walls, and kicking sites of irritation may compromise a CVC, and the risk of CVC-related complications is amplified by long-term use. Thus, safe and uncomplicated maintenance of a CVC in swine requires careful consideration of CVC choice, placement, securement, protection, sanitation, and surveillance.
The Hickman catheter (HC) used in this protocol is a tunneled CVC with a polyester cuff and one to three lumens, that is commonly used for long-term intravenous access in humans and animals1,4,8,9. The tunneled catheter approach has been associated with lower complication rates and maintenance costs relative to non-tunneled variations10,11,12. The cuff reduces HC extrication by incorporating into the subcutaneous tissues surrounding the skin exit site. The multi-lumen design also enables the separation of medication administration and blood draws, thereby minimizing blood sample contamination and inaccuracy. Despite this, HC use is not without challenges, the most common of which include fracture, migration, occlusion, and infection13,14,15,16. Proper installation and maintenance of a HC are therefore indispensable skills when used in translational research. However, the current literature offers little guidance for best-practices for HC use in swine during long-term trials5,6,17.
The purpose of this study is to outline an optimized approach for HC insertion into the internal jugular vein (IJV), skin securement, and durable protection that minimizes long-term catheter-related complications and discomfort in swine. A discussion of the important considerations for HC use, potential challenges that may be encountered, and modifications that may improve the quality of this approach is included.