-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Biochemistry
Sample Preparation and Transfer Protocol for In-Vacuum Long-Wavelength Crystallography on Beamlin...
Sample Preparation and Transfer Protocol for In-Vacuum Long-Wavelength Crystallography on Beamlin...
JoVE Journal
Biochemistry
This content is Free Access.
JoVE Journal Biochemistry
Sample Preparation and Transfer Protocol for In-Vacuum Long-Wavelength Crystallography on Beamline I23 at Diamond Light Source

Sample Preparation and Transfer Protocol for In-Vacuum Long-Wavelength Crystallography on Beamline I23 at Diamond Light Source

Full Text
3,068 Views
10:32 min
April 23, 2021

DOI: 10.3791/62364-v

Ramona Duman1, Christian M. Orr1, Vitaliy Mykhaylyk1, Kamel El Omari1, Robert Pocock1, Vinay Grama1, Armin Wagner1

1Diamond Light Source Ltd, Harwell Science & Innovation Campus

Here, we present a protocol for cryogenic sample preparation and transfer of crystals into the vacuum endstation on beamline I23 at Diamond Light Source, for long-wavelength macromolecular X-ray crystallography experiments.

Long-wavelength macromolecular crystallography exploits the anomalous signal from light atoms natively present in proteins and nucleic acids. This technique is used to experimentally solve the crystallographic face problem and to determine the identity and location of these elements. Beamline I23 at Diamond Light Source is a unique synchrotron instrument optimized for experiments at long wavelengths up to five angstrom.

It allows access to the absorption edges of elements of high biological relevance, such as calcium, potassium, chlorine, sulfur, and phosphorus. Due to the significant absorption of x-rays by air in the long-wavelength regime, these experiments are performed in a vacuum environment. To keep samples at cryogenic temperatures inside the vacuum environment, the crystals are mounted on dedicated, thermally-conductive sample holders.

The cryogenic sample transfer from liquid nitrogen to the vacuum end station is very similar to the techniques used in cryo-electron microscopy. This protocol presents the procedure for transferring crystals into the vacuum environment using the tools and equipment developed at Diamond Light Source. Begin by separating the lid from the base of the CombiPuck such that the sample holders remain attached to the base and vials are retained in the lid.

Immerse the lid with vials in liquid nitrogen, then attach a sample holder and adapter to a magnetic wand and harvest the crystals. Flush cool each sample directly into the CombiPuck, noting the sample position. To close the puck, use a puck wand to attach the base to the lid.

Transfer the CombiPuck from liquid nitrogen to the dry shipper or storage. Place the base of the block puck already populated with empty transfer blocks onto its support base in a foam container, then fill with liquid nitrogen. Then, place the CombiPuck in the foam container filled with liquid nitrogen, making sure that the base of the puck is secured to the magnetic holder inside the foam container.

Pre-cool all necessary tools in liquid nitrogen. Then, separate the lid from base using the puck separator tool on the high setting, such that the base remains attached to the magnetic holder, exposing the sample holders inside liquid nitrogen. Place the separator wand over the sample holder and adapter as far down as it can go, making sure the wand is vertical.

Move the small lever on the separator wand down with your thumb until it clicks to secure the sample holder inside, and pull the sample holder from the adapter. Lower the separator over the desired transfer block position, making sure one of the three prongs fit inside the central hole of the transfer block. Release the sample holder by moving the lever back up.

To load samples into the next transfer block, use the carousel key tool to rotate an empty transfer block into the horizontal position. Once all sample holders are transferred, close the block puck by placing the lid in liquid nitrogen. Wait for the temperature to equilibrate, and then fit the lid over the base and lift gently to release from the carousel.

Attach the shuttle to the station. Open the nitrogen gas and air valves and ensure that gases are flowing. Then, switch on the CTS.

Cool both the bath and the shuttle with liquid nitrogen. Place the supplied funnel in the filling port on the shuttle and slowly pour liquid nitrogen into the funnel while monitoring the level on the screen. Stop when the indicator turns from red to blue.

Fill the bath with liquid nitrogen using the funnel. Transfer a block puck from liquid nitrogen to the CTS bath using the attached puck separator tool. Remove the lid of the block puck and close the lid of the CTS bath.

To introduce a transfer block into the shuttle, unlock the shuttle handle by rotating 90 degrees clockwise and advance it towards the bath so that the guided track on the handle enforces the correct path of travel. Once the block cover is cooled, advance the handle to introduce the block into the shuttle. To lock the transfer block onto the shuttle, rotate the handle 180 degrees clockwise.

Retract the handle to the original back position, and lock it in place by rotating 90 degrees counterclockwise. Press Close Shuttle Valve Pump on the display screen to start shuttle evacuation. Once the messages Shuttle ready to move and Do not move rod, valve closed are displayed on the touch screen, press the lever underneath the shuttle and carefully lift it using the handle at the top.

Carry the shuttle to the airlock on the vacuum end station in an upright position and attach it. Select an empty block position within the vessel by pressing the corresponding button on the touch screen and moving the sample hotel to the correct loading position. Once a sample hotel is in position, press the Open button to initiate the vacuum interlock sequence.

After the sequence is complete and the status changes to Airlock open, block in shuttle, twist the handle 90 degrees clockwise to unlock the rod. Gently push the rod into the vessel so that the guided track enforces the correct path of travel towards the sample hotel. Slowly insert the transfer block into the hotel using the video feed displayed on the screen for guidance, ensuring that the block position icon on the touch display is activated.

Once activated, rotate the handle 180 degrees counterclockwise to release the transfer block and pull the rod out of the vessel. Once fully retracted, rotate the handle 90 degrees counterclockwise to lock the rod. Press the Close button to close the end station vacuum valve and vent the space between the shuttle and the vessel to atmospheric pressure.

Remove the shuttle when the airlock display shows the status OK to detach. Return the shuttle to the CTS bath and press Open Shuttle Valve to evacuate the shuttle before loading the next sample block. Once the traffic light is green and the message OK to move rod appears, the next transfer block can be introduced to the shuttle.

To prepare the next transfer block, rotate the block puck inside the bath. Push the built-in rotation key on the top of the acrylic lid down into the lock in the center of the block puck. While holding it down, turn the key to position the desired transfer block in the pickup position.

Once all blocks have been transferred, ensure the shuttle valve is open, press the Bake button on the touch screen, select both Bath and Shuttle, then press Start Bake. The long-wavelength macromolecular crystallography beamline I23 at Diamond Light Source can access the absorption edges of elements of high biological importance, such as calcium, potassium, chlorine, sulfur, and phosphorus, giving enhanced anomalous signal which can be used for phasing or locating these elements within macromolecules. Diffraction data were collected from a single thaumatin crystal at wavelength 2.75 angstrom, chosen as a compromise between increased anomalous signal and sample absorption effects at longer wavelengths.

The vacuum setup ensures that only x-rays scattered by the sample reach the detector, providing low background around the Bragg reflections. The dataset yielded very strong anomalous signal, facilitating structure solution by the automatic phasing pipeline CRANK2. The high quality of the resulting electron density map enabled successful automatic model building, with correct placement for 100%of the amino acid sequence of thaumatin.

The 16 cysteine residues within thaumatin form eight disulfide bridges, which are all clearly visible in the electron density map. Since in-vacuum long-wavelength protein crystallography is a new field, we have developed new sample handling tools and equipment. This protocol guides users in safely transferring samples into the vacuum end station on beamline I23 at Diamond Light Source.

The vacuum environment opens unique opportunities to perform diffraction experiments in a wavelength range not accessible at other beamlines. Long-wavelength x-ray crystallography enables experimental phasing of macromolecules directly from native crystals. It also allows unambiguous identification of ions bound to the molecules.

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Sample PreparationTransfer ProtocolIn-vacuum CrystallographyLong-wavelengthBeamline I23Diamond Light SourceMacromolecular CrystallographyAnomalous SignalVacuum EnvironmentCryogenic TemperaturesSample HoldersCombiPuckLiquid NitrogenX-ray AbsorptionBiological RelevanceCryo-electron Microscopy

Related Videos

Angle-resolved Photoemission Spectroscopy At Ultra-low Temperatures

08:53

Angle-resolved Photoemission Spectroscopy At Ultra-low Temperatures

Related Videos

18K Views

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Related Videos

8.8K Views

Fixed Target Serial Data Collection at Diamond Light Source

06:19

Fixed Target Serial Data Collection at Diamond Light Source

Related Videos

3.7K Views

Cryo-Structured Illumination Microscopic Data Collection from Cryogenically Preserved Cells

11:55

Cryo-Structured Illumination Microscopic Data Collection from Cryogenically Preserved Cells

Related Videos

4.5K Views

A Sample Preparation Pipeline for Microcrystals at the VMXm Beamline

09:00

A Sample Preparation Pipeline for Microcrystals at the VMXm Beamline

Related Videos

3.3K Views

Achieving Efficient Fragment Screening at XChem Facility at Diamond Light Source

08:35

Achieving Efficient Fragment Screening at XChem Facility at Diamond Light Source

Related Videos

6.6K Views

Preparation and Delivery of Protein Microcrystals in Lipidic Cubic Phase for Serial Femtosecond Crystallography

09:09

Preparation and Delivery of Protein Microcrystals in Lipidic Cubic Phase for Serial Femtosecond Crystallography

Related Videos

11.8K Views

Biochemical and Structural Characterization of the Carbohydrate Transport Substrate-binding-protein SP0092

08:53

Biochemical and Structural Characterization of the Carbohydrate Transport Substrate-binding-protein SP0092

Related Videos

31.2K Views

An All-in-one Sample Holder for Macromolecular X-ray Crystallography with Minimal Background Scattering

07:55

An All-in-one Sample Holder for Macromolecular X-ray Crystallography with Minimal Background Scattering

Related Videos

13.7K Views

Cell Culture on Silicon Nitride Membranes and Cryopreparation for Synchrotron X-ray Fluorescence Nano-analysis

08:26

Cell Culture on Silicon Nitride Membranes and Cryopreparation for Synchrotron X-ray Fluorescence Nano-analysis

Related Videos

9.8K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2025 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code