Organ-specific hemodynamics are important physiological features of any mammalian organ. Abnormalities in blood flow may be the consequence of inflammation and a sign of organ dysfunction1. Thus, blood flow organization, structure and function appear as critical parameters for analysis under physiological and pathological conditions. The techniques that have been commonly used for analyzing blood flow in a specific organ contain several limitations, including the resolution limit of the technique itself (e.g. Doppler imaging of blood flow), the capacity for measurement of absolute blood flow only (volume of blood per unit serving an organ) (e.g. Optical Coherence tomography) and the measurement of average changes in speed in a large and heterogeneous population of blood vessels2,3. The liver’s circulatory system links different vessel subtypes that are heterogeneous in their size, structure and function. In this study, intravital microscopy (IVM) imaging technology is applied to evaluate liver hemodynamics in vivo, in real time, at high resolution and in parallel to uncover the characteristics of the individual blood vessels that comprise the hepatic organ. The recent development of this powerful optical imaging technique allows the researcher to collect dynamic data on living animals at a high spatial and temporal resolution. By allowing the direct visualization and real time monitoring of specific and rapid biological processes in vivo, IVM provides a unique opportunity to the researcher to image individual blood vessels, and measure and quantify the velocity of single red blood cells (RBC) within a specifically selected hepatic vessel.
In this study, we have implemented the IVM technique in the mouse liver to investigate the influence of mouse infection by the hepatotropic Leishmania parasite on liver hemodynamics. L. donovani is the agent responsible for visceral leishmaniasis, a severe disease characterized by acute-on-chronic inflammatory responses and a pathology that is present in multiple organs, including the spleen and the liver. In an experimental mouse model of visceral leishmaniasis, the liver infection is self-resolving whereas the splenic infection is progressive4. These outcomes of Leishmania infection with respect to the individual organs are still not completely understood. Investigation of liver and spleen hemodynamics under pathological conditions will shed new light on host-parasite interactions and disease pathogenesis.
Our experimental model system is based on exposing and imaging the liver of an anesthetized mouse that received intravenous injection of specific fluorescent dyes for the labeling of the hepatic intravasculature. The liver is a favorable organ for intra-vital microscopy. After performing a small incision in the abdomen, the liver is gently externalized and placed on wet gauze, then on a coverslip with the goal of reducing any motion artifacts due to heartbeat and respiration. The liver is then placed within the view of a microscope lens. As compared to the spleen and lymph node which require the use of two photon microscopy for IVM studies, the advantage of the liver lies in its homogenous 3D architecture/anatomy that allows for the use of a conventional confocal microscope, with a maximum penetration depth of approximately 50 μm, for intravital microscopy imaging5-8.
This study describes two independent imaging methods for the quantitative measurement of RBC velocity and blood flow speed in individual blood vessels. In the first method, liver blood flow is acquired using a xy bi-dimensional mode over time. The resulting xyt data are analyzed using the MtrackJ plugin in the free ImageJ software, which allows for the tracking of individual RBCs over time. In the second method, a single blood vessel is selected and its corresponding blood flow is analyzed using the line scanning fast acquisition mode of the confocal laser-scanning microscope. The vessel of interest is scanned at high frequency along its central axis through an axial line. The blood flow velocity is then quantified based on the difference in contrast between unlabeled dark erythrocytes and fluorescently labeled plasma. The fluorescence intensities of RBCs and plasma acquired along the line scan are plotted against time to obtain streaks, the angles of which are proportional to the velocities of an individual RBC.
The goal of this article is to provide a simple and reproducible method for imaging and measuring blood flow velocity within individual blood vessels of the liver and to make available the basic tools for the successful performance of mouse surgery, IVM and quantitative analyses of the velocity of individual RBCs. This approach will allow researchers to gain new insights into blood velocity under pathological conditions.