X-ray fluorescence imaging allows for both the identity and quantity of elements present in a sample to be spatially resolved. Incident X-rays, of an energy selected to be greater than the electron binding energy of the heaviest element of interest, overcome the binding energy of inner-shell electrons to the nucleus1. This creates a ‘hole’ in the electron shell. As higher-energy electrons fall down into these holes, fluorescent X-rays are emitted whose wavelength is dependent on the energy separation of those orbitals. Since the energy spacing of the orbitals is characteristic of a given element, the X-ray fluorescence emission also has characteristic wavelengths, dependent on the element. It is this emission at a characteristic wavelength that allows the identification of the elements present. Calibration of the fluorescence intensity allows the quantitation of the elements present.
X-ray fluorescence microscopy (XFM) has become increasingly utilized, partly due to the development of very brilliant X-ray synchrotron sources, such as those at Spring-8 in Japan, the European Radiation Synchrotron Facility (ESRF) in France, and the Advanced Photon Source (APS) in the US2. These sources provide very high intensity X-ray beams. At the same time, improvements in X-ray optics, such as zone plate technology, allowed the focusing of these beams to sub-micron spots, albeit rather inefficiently3. With very high-intensity beams, even a relatively small amount of light that can be focused is sufficient to excite the endogenous metals in cells, producing signal that can be measured with currently available detector technology. Thus, studying the chemical biology of metals in the cell is one application in particular that makes use of many of the recent developments in this technique4-10.
There are many critical factors to be considered while applying XFM to investigate the elemental distribution and quantification of cultured mammalian cells or other biological samples. Firstly, the sample needs to be kept intact, both structurally and with respect to its elemental composition, in order for the measurement to be meaningful. Secondly, the sample must also be preserved in some way so that it is hardy to the radiation damage that can be caused by a focused X-ray beam. One way that a sample can meet both of these criteria at once is to be rapidly frozen into a vitreous, amorphous ice11,12. Rapid freezing is often achieved through various cryopreservation techniques such as plunge freezing or high pressure freezing13-16. It is generally accepted that cryopreservation preserves overall cellular architecture and chemical compositions in biological samples as close to native state as possible. Chemical fixation, on the other hand, due to the slow and selective penetration of fixatives into cells and tissues as well as subsequent changes in membrane permeability, may allow various cellular ions especially the diffusible ions such as Cl, Ca and K to be leached, lost or relocated, thus rendering investigation of these elements suboptimal17-19. Despite the clear advantage of cryo-fixation over chemical fixation in general, for adherent mammalian cells in particular, cryopreservation has various limitations20-23. The most obvious one is that not every research lab has easy access to cryopreservation instruments. Most current high pressure freezers or even plunge freezers are costly and owned only by a subset of cryo facilities, which may be far from where cells are incubated. The benefit of cryopreservation might be traded for the disadvantage of travel stress placed on the cells. Thus, while cryopreservation is surely the most rigorous way to preserve samples for X-ray fluorescence analysis, it is certainly not the most accessible to all researchers under all circumstances; nor is it always essential — if the metals of interest are tightly bound to fixable macromolecules, and the resolution at which the sample will be imaged is greater than the damage to the ultra-microstructure that might occur during drying. Mindful of the caveats24, chemical fixation and drying may be a suitable choice.
Other factors in a successful X-ray fluorescence imaging experiment include proper analysis. X-ray fluorescence imaging is fundamentally X-ray fluorescence emission spectroscopy combined with raster-scanning to provide spatial resolution. The X-ray fluorescence emission spectra collected contain a combination of overlapping emission peaks, background, and the elastic and inelastic scattering peaks of the incident beam. Software that enables the de-convolution of these contributions, and the fitting of the emission peaks, has been a critical development to this field25. Also, the development and commercial distribution of thin-film standards of known composition, used to calibrate fluorescence intensity relative to material quantity, has also been very important.
This protocol provides a description of the preparation of adherent cells by chemical fixation and air drying. A vital step in this process is the growth of the cells on the silicon nitride windows, which often do not adhere well, making gentle rinsing in a particular fashion key to success.