-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Bioengineering
Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical...
Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical...
JoVE Journal
Bioengineering
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Bioengineering
Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

Full Text
8,737 Views
12:22 min
August 4, 2018

DOI: 10.3791/57814-v

Weiye Song*1, Libo Zhou*1, Ji Yi1,2

1Department of Medicine,Boston University School of Medicine, 2Department of Biomedical Engineering,Boston University

Summary

Here, we present a protocol to get a large field of view (FOV) three-dimensional (3D) fluorescence and OCT retinal image by using a novel imaging multimodal platform. We will introduce the system setup, the method of alignment, and the operational protocols. In vivo imaging will be demonstrated, and representative results will be provided.

Transcript

This method can help answer key questions in the field of ophthalmology and retinal imaging. Such as imaging and quantification of blood-retina barrier disruption and retinal capillary functions. The main advantage of this technique is that it can obtain a large field of view, three-dimensional, multi-contrast retinal imaging by using an oblique scanning laser in one single raster scan.

The implications of this technique extend toward diagnosis of diabetic retinopathy and other pre-retinal diseases. Because oSLO can obtain high-contrast images of retinal microvasculature, down to single capillaries in 3D. Though this method can provide insight into retinal imaging, it can also be applied to other imaging systems using conventional objective lens.

Such as in vivo imaging of the mouse cortex. A super-continuum laser source is used as the system laser source for the oblique scanning laser ophthalmoscopy, or oSLO setup. The visible light range is separated from higher-wavelength range by the first dichroic mirror.

The light spectrum is expanded with a pair of dispersive prisms, after the beam passes through a polarization beam splitter. A slit is used to select the excitation wavelength range. And a reflective mirror reflects the filtered beam back to the prism pair to couple the light into a single-mode fiber.

A spectrometer is used to confirm the wavelength selection at the output of the single-mode fiber. The single-mode fiber is connected to two cascaded optical fiber couplers. One of the fiber output port from the second fiber coupler delivers the light to the oSLO system.

To collimate the laser in the oSLO system, the laser is deflected by a galvanometer mirror. A one-to-one telescope system relays the laser to a second galvanometer mirror, and a three-to-one telescope system further relays the laser to the pupil of the eye. A dichroic mirror within the three-to-one telescope system reflects the fluorescent signals.

The three-to-one telescope system and the dichroic mirror is mounted on a customized dovetail slider to offset the optical axis and create the oblique scanning illumination. The oblique illumination allows the volumetric fluorescence imaging without a need to have sectioning. By offsetting the laser, an oblique beam is focused on retina, and then the oblique detection can capture a tomographic fluorescence image along the oblique beam path.

To create the fluorescence imaging optical path, the fluorescence is reflected by the dichroic mirror and relayed to the third galvanometer mirror. The fluorescent light is then relayed to an imaging objective lens by another one-to-one telescope system. Two additional translation stages are installed under the third galvanometer mirror to provide redundancy in the degrees of freedom for optimizing the image.

The final imaging system is mounted on a stage that has three degrees of freedom. Rotation, and two axes of translation. A planar camera is used to capture the cross-sectional fluorescence images.

Another dichroic mirror separates the rear infrared range from the remaining light. A long pass filter is used to further limit the bandwidth to 800 to 900 nanometers. Couple the beam into a single-mode fiber.

The single-mode fiber is connected to the other input port of the two cascaded optical fiber couplers to combine with the blue oSLO excitation. The light from the second output port of the second fiber coupler is directed to the OCT reference arm. Which has dispersion compensation plates, variable neutral density filter, and a reflective mirror.

The light return from the reference arm and the eye recombines at the second optical fiber coupler, and is delivered to the OCT spectrometer to collect the signal. Use a data acquisition system software written in Labview and modified from the scanning OCTA scanning protocol. For each b-scan, an 80%duty cycle sawtooth with 500 steps is output by an analog output board to control the x-prime fast scanning mirror.

Trigger the line scan camera at each step to acquire data for the OCT, only when the mirror is in the forward scanning direction. Set the exposure time for the line scan camera to be 17 microseconds. To acquire the OCTA signal, repeat the measurement five times at the same b-scan location.

Set the AO output rate at 100 kilohertz, and the OCT A-line rate at 50 kilohertz. Control the y-prime slow scanning mirror, GM1, by a ramping waveform. Synchronize the descanning mirror, GM3, with GM1 to descan the slow scanning.

Trigger the planar camera by another analog output board to capture one fluorescent image at each y-prime location. Crop the imaging size or bin the neighbor pixels to increase the speed and sensitivity as desired. Begin by confirming an appropriate level of anesthesia in the rat by a lack of a withdrawal reflex during an intradigital pinch.

After anesthesia induction, place the rat on a holder. Fit a nose cone to maintain the anesthesia during the remainder of the experiment. Apply 5 tetracaine hydrochloride ophthalmic solution on the rat's eye for local anesthesia.

Then dilate the pupil with 1%tropicamide ophthalmic solution. After two minutes of dilation, use a one-milliliter syringe and a 29-gauge needle to inject 10%fluorescein or 10%FITC diluted in saline through the tail vein. Then turn on the laser source, and place a neutral density filter to attenuate the blue light excitation during alignment.

Measure the power of blue light, ensuring that it is less than 10 microwatts. Then switch to the optical coherence tomography light, ensuring that it is close to 8 milliwatts. Turn on the power supply to the galvanometer mirror, which is used to control the direction of the laser.

Adjust the height of the eyeball to make a stationary laser spot on the cornea. Adjust the eye position to make the rim of the pupil roughly perpendicular to the laser. And offset the laser to about 1.5 millimeters from apical center of the eye.

Further adjust the animal holder until the optical coherence tomography images reach optimal quality. In the x-prime fast scanning direction, make sure that the cross-sectional b-scan image appears flat. When switching to the y-prime slow scanning direction, make sure the cross-section b-scan image appears tilted due to the oblique scanning.

Remove the neutral density filter to the blue light excitation. And monitor the real-time feed from the camera. A cross-sectional fluorescent image should appear showing blood vessels at different depths.

Adjust the focus of the final fluorescence imaging system to reach the optimal focus. And perform fine adjustments of the eye position in the lateral plane to reach optimal oblique scanning laser ophthalmoscopy image quality. After the alignment, begin to acquire simultaneous optical coherence tomography angiography and volumetric fluorescein angiography.

This image shows a cross-sectional optical coherence tomography image of a rat retina. This is an optical coherence tomography angiography, or OCTA image, of the same region. And an oblique scanning laser ophthalmoscopy and volumetric fluorescein angiography image cross-sectional fluorescein angiography, or oSLO-VFA.

Analogous to the optical coherence tomography b-scan. In comparison to OCTA, the oblique scanning laser ophthalmoscopy and volumetric fluorescein angiography cross-sectional image clearly identifies the capillaries in the outer plexiform layer. The superficial layer of the retina is shown here in an OCTA image.

Artefacts in the form of vertical stripes are visible in the image. oSLO-VFA avoids the motion artefacts by utilizing fluorescence emission contrast. Within the retinal intermediate layer, the vertically-diving vessels are clearly shown in the oSLO FA image.

But not apparent in OCTA. While attempting this procedure, it's important to avoid the continuous laser exposure to the eye for more than two minutes. Avoid corneal drying, and allow the eye to rest at least 30 seconds between imaging sections by blocking the light.

Following this procedure, other methods like imaging genetically-modified mice to express fluorescence proteins can be performed in order to answer additional questions. Like how specific retinal cell types can change, and the pulling past seen variables with known diseases.

Explore More Videos

MultimodalVolumetricRetinal ImagingOblique Scanning Laser Ophthalmoscopy (oSLO)Optical Coherence Tomography (OCT)Blood-retina Barrier DisruptionRetinal Capillary FunctionsDiabetic RetinopathyPre-retinal DiseasesIn Vivo ImagingMouse CortexSuper-continuum LaserDichroic MirrorPrismSpectrometerOptical Fiber CouplerGalvanometer MirrorTelescope SystemOblique IlluminationTomographic Fluorescence Imaging

Related Videos

Doppler Optical Coherence Tomography of Retinal Circulation

10:46

Doppler Optical Coherence Tomography of Retinal Circulation

Related Videos

19K Views

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

11:21

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

Related Videos

11.7K Views

In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography

04:08

In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography

Related Videos

381 Views

Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo

08:17

Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo

Related Videos

19.7K Views

Ultrahigh Resolution Mouse Optical Coherence Tomography to Aid Intraocular Injection in Retinal Gene Therapy Research

10:10

Ultrahigh Resolution Mouse Optical Coherence Tomography to Aid Intraocular Injection in Retinal Gene Therapy Research

Related Videos

9.5K Views

In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy

06:19

In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy

Related Videos

10.9K Views

Novel Photoacoustic Microscopy and Optical Coherence Tomography Dual-modality Chorioretinal Imaging in Living Rabbit Eyes

09:20

Novel Photoacoustic Microscopy and Optical Coherence Tomography Dual-modality Chorioretinal Imaging in Living Rabbit Eyes

Related Videos

11.1K Views

Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats

07:08

Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats

Related Videos

10.3K Views

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography

07:44

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography

Related Videos

3.2K Views

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy

08:22

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy

Related Videos

4.7K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2025 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code