-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Bioengineering
Optical Mapping of Action Potentials and Calcium Transients in the Mouse Heart
Optical Mapping of Action Potentials and Calcium Transients in the Mouse Heart
JoVE Journal
Bioengineering
This content is Free Access.
JoVE Journal Bioengineering
Optical Mapping of Action Potentials and Calcium Transients in the Mouse Heart

Optical Mapping of Action Potentials and Calcium Transients in the Mouse Heart

Full Text
28,064 Views
08:13 min
September 13, 2011

DOI: 10.3791/3275-v

Di Lang1, Matthew Sulkin1, Qing Lou1, Igor R. Efimov1

1Department of Biomedical Engineering,Washington University in St. Louis

This paper details the dissection procedure, instrumental setup, and experimental conditions during optical mapping of transmembrane potential (Vm) and intracellular calcium transient (CaT) in intact isolated Langendorff perfused mouse hearts.

The overall goal of this procedure is to simultaneously optically map transmembrane potential and intracellular calcium transient in intact isolated LOR perfused mouse hearts. This is accomplished by first excising the intact mouse heart, then cannulating the aorta and beginning LOR perfusion. The next step is to immobilize the heart by loading an excitation contraction on coupler and then pinning the heart to the perfusion chamber.

The final steps are to load the optical dyes and make preparations to reduce motion artifacts during the experiment. Optical images are obtained by collecting the light emitted from the heart with my cam Ultima LC Moss cameras. Hey, my name's di.

I'm a graduate student in Washington University. The main advantage of this technique over existing method, like micro electrode, is that optical mapping allows for greater spatial resolution over the entire surface of the heart. Hi, I'm Matt Sulkin.

I'm a graduate student at Washington University. This method, if done correctly, can help answer many questions in cardiac electrophysiology such as the basis of arrhythmogenesis. Begin by configuring one peristaltic pump to circulate the solutions at 40 milliliters per minute.

Then set a second peristaltic pump to 80 milliliters per minute. This pump returns the Perfuse eight back to the holding and oxygenating reservoir. Turn on the pumps and wash the system with one liter, 70%ethanol for 30 minutes with recirculation.

Follow this wash with two liters of deionized water without recirculation. Once the water is evacuated, circulate two liters of Tyro solution and pass it through a five micron filter. Warm the perfuse eight to 37 degrees Celsius with a water jacket and circulator bubble oxygenated gas into the solution.

Adjust the rate of gas bubbling to maintain the pH at 7.35 plus or minus 0.05. Monitor both the pH and temperature during experiment. The dual optical mapping apparatus consists of two high speed C moss cameras that can capture a 100 by 100 pixel image at 3000 frames per second.

Attach a band pass filter to the calcium imaging camera and attach a long pass Filter to the voltage imaging camera on a dual camera holder. Attach a diic mirror and lens so that emission light coming from the heart is focused onto the mirror by the lens. Also, attach two cameras to the holder and arrange them so they are perpendicular to one another.

Next, set up the excitation light. The light is generated by a halogen lamp and directed through a flexible light guide. Pass the light through a heat filter, a shutter to limit exposure, and an excitation band pass filter.

Finally, prepare silver and silver chloride electrodes by installing them in the chamber. After double checking and adjusting the levels on the amplifiers and filters, the setup is ready for a heart. Use a cocktail of ketamine and xylazine with 100 units of heparin to anesthetize a mouse before proceeding.

Assure that the animal has no pain reflex using a toe pinch. After making a mid sternal incision, quickly remove the heart and the surrounding tissues. Then using dissecting microscope rapidly, identify the aorta and make a clean cut across the ascending aorta below the right subclavian artery.

Now attach a short section of aorta to a custom made 21 gauge cannula using four oh black braided silk sutures After cannulation retro greatly perfu and super fuse the heart. With Tyro solution, adjust the flow rate to keep the aortic pressure between 60 and 80 millimeters. Mercury as measured by a pressure transducer.

Now dissect and remove the surrounding lung thymus and fat tissue. Now insert a silicone tube into the left ventricle through the pulmonary veins. Suture the tube to nearby connective tissue.

This very important step prevents congestion and acidification of Perfuse eight trapped in the left ventricle, especially after the suppression of ventricular contractions. To prevent Perfuse eight induced heart movements, pin the heart to the bottom of the sill guard coated perfusion chamber at its apex. Furthermore, stretch and pin down the right and left atrial appendages to increase the surface area of the atria in the upright configuration.

This will maximize recording surface area. To conduct the pacing stimulations, attach a custom made electrode to the surface of the heart. To reduce motion artifacts, fix a small cover glass over the heart on the solution surface.

Do this by wedging the glass between several pins. As final preparations, focus the excitation light on the heart and position the cameras to get an optical image then commence with loading the dye while loading dies. Continuously monitor ECG recordings to assure normal electrical function of the heart.

Begin with warming up BLEs statin to room temperature. Then mix one half milliliter of BLEs statin into the profuse eight in the holding reservoir, and dilute the remaining one 10th milliliter of BLEs statin into one milliliter of Tyros solution. Over the next 20 minutes, slowly inject the BLEs statin in tyros through a drug port near the cannula.

The BLEs statin will gradually reduce the motion artifact. Next, dilute 30 microliters of voltage sensitive dye into one milliliter tyro solution, and slowly inject this mixture over five to seven minutes into the same drug port. Then make the same mixture again.

This time, adding an additional 30 microliters of calcium indicator. Slowly apply this mixture over five to 10 minutes through the same port. After the calcium indicator is injected, wait an additional five to 10 minutes for the BLEs statin to fully suppress motion, and for the dyes to enter the cells before proceeding with the experiment.

This heart preparation was made. According to the protocol, ECG signals were recorded during ventricular pacing from S one S one stimulation. Action potentials and calcium transient signals were recorded from the atria on the left and ventricles on the right.

The arrow shows where signal scattering from the ventricles occurred by binning the recordings from the camera in units of three pixels by three pixels, an array of calcium transients and action potentials can be displayed from the data from the array data. A figure showing action potential conduction can be constructed. Data from three consecutive points on the transverse and longitudinal axis show the amplitude change with the propagation of the action potential across a ventricular surface.

Likewise, a figure showing action potential and calcium transient durations can be constructed. This shows a control condition on the left on the right. An injection of isoproterenol was given to the heart, which clearly shortens the duration of both calcium transients and action potentials.

Once mastered, this technique can be completed in two to three hours Following this procedure. Other methods like pacing protocol can be performed in order to answer additional questions such as those regarding refractory period of AV node.

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Optical MappingAction PotentialsCalcium TransientsMouse HeartCardiovascular StudiesFluorescence ImagingGenetic EngineeringPhysiological PhenotypingTransmembrane Potential (Vm)Excitation-contraction CouplingLangendorff Perfused Mouse HeartsHeart FailureArrhythmiasMetabolic DiseaseHeart DiseasesActivation VisualizationConduction VelocityAction Potential DurationInstrumentation SetupExperimental ConditionsSpatio-temporal ResolutionCMOS Imaging Technology

Related Videos

Optical Mapping of Langendorff-perfused Rat Hearts

11:48

Optical Mapping of Langendorff-perfused Rat Hearts

Related Videos

21.3K Views

Multiparametric Optical Mapping of the Langendorff-perfused Rabbit Heart

09:24

Multiparametric Optical Mapping of the Langendorff-perfused Rabbit Heart

Related Videos

23.2K Views

Voltage and Calcium Dual Channel Optical Mapping of Cultured HL-1 Atrial Myocyte Monolayer

08:25

Voltage and Calcium Dual Channel Optical Mapping of Cultured HL-1 Atrial Myocyte Monolayer

Related Videos

10.8K Views

Optical Mapping of Intra-Sarcoplasmic Reticulum Ca2+ and Transmembrane Potential in the Langendorff-perfused Rabbit Heart

09:26

Optical Mapping of Intra-Sarcoplasmic Reticulum Ca2+ and Transmembrane Potential in the Langendorff-perfused Rabbit Heart

Related Videos

9.7K Views

High-resolution Optical Mapping of the Mouse Sino-atrial Node

11:07

High-resolution Optical Mapping of the Mouse Sino-atrial Node

Related Videos

16.7K Views

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping

08:19

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping

Related Videos

10.4K Views

High-Throughput Analysis of Optical Mapping Data Using ElectroMap

07:36

High-Throughput Analysis of Optical Mapping Data Using ElectroMap

Related Videos

10K Views

Optical Imaging of Isolated Murine Ventricular Myocytes

11:32

Optical Imaging of Isolated Murine Ventricular Myocytes

Related Videos

6.7K Views

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts

09:52

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts

Related Videos

13.7K Views

Preclinical Cardiac Electrophysiology Assessment by Dual Voltage and Calcium Optical Mapping of Human Organotypic Cardiac Slices

09:35

Preclinical Cardiac Electrophysiology Assessment by Dual Voltage and Calcium Optical Mapping of Human Organotypic Cardiac Slices

Related Videos

10.7K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code